After the change from revision 30103, nixos-rebuild suddenly consumed freaky amounts of memory. I had to abort the process after it had allocated well in excess of 30GB(!) of RAM. I'm not sure what is causing this behavior, but undoing that assignment fixes the problem. The other two commits needed to be revoked, too, because they depend on 30103. svn path=/nixos/trunk/; revision=30127
276 lines
7.6 KiB
Nix
276 lines
7.6 KiB
Nix
{config, pkgs, ...}:
|
|
|
|
# TODO: This is not secure, have a look at the file docs/security.txt inside
|
|
# the project sources.
|
|
with pkgs.lib;
|
|
|
|
let
|
|
cfg = config.power.ups;
|
|
in
|
|
|
|
let
|
|
upsOptions = {name, config, ...}:
|
|
{
|
|
options = {
|
|
# This can be infered from the UPS model by looking at
|
|
# /nix/store/nut/share/driver.list
|
|
driver = mkOption {
|
|
type = types.uniq types.string;
|
|
description = ''
|
|
Specify the program to run to talk to this UPS. apcsmart,
|
|
bestups, and sec are some examples.
|
|
'';
|
|
};
|
|
|
|
port = mkOption {
|
|
type = types.uniq types.string;
|
|
description = ''
|
|
The serial port where your UPS is connected. /dev/ttyS0 is
|
|
usually the first port on Linux boxes, for example.
|
|
'';
|
|
};
|
|
|
|
shutdownOrder = mkOption {
|
|
default = 0;
|
|
type = types.uniq types.int;
|
|
description = ''
|
|
When you have multiple UPSes on your system, you usually need to
|
|
turn them off in a certain order. upsdrvctl shuts down all the
|
|
0s, then the 1s, 2s, and so on. To exclude a UPS from the
|
|
shutdown sequence, set this to -1.
|
|
'';
|
|
};
|
|
|
|
maxStartDelay = mkOption {
|
|
default = null;
|
|
type = types.uniq (types.nullOr types.int);
|
|
description = ''
|
|
This can be set as a global variable above your first UPS
|
|
definition and it can also be set in a UPS section. This value
|
|
controls how long upsdrvctl will wait for the driver to finish
|
|
starting. This keeps your system from getting stuck due to a
|
|
broken driver or UPS.
|
|
'';
|
|
};
|
|
|
|
description = mkOption {
|
|
default = "";
|
|
type = types.string;
|
|
description = ''
|
|
Description of the UPS.
|
|
'';
|
|
};
|
|
|
|
directives = mkOption {
|
|
default = [];
|
|
type = types.listOf types.string;
|
|
description = ''
|
|
List of configuration directives for this UPS.
|
|
'';
|
|
};
|
|
|
|
summary = mkOption {
|
|
default = "";
|
|
type = types.string;
|
|
description = ''
|
|
Lines which would be added inside ups.conf for handling this UPS.
|
|
'';
|
|
};
|
|
|
|
};
|
|
|
|
config = {
|
|
directives = mkHeader ([
|
|
"driver = ${config.driver}"
|
|
"port = ${config.port}"
|
|
''desc = "${config.description}"''
|
|
"sdorder = ${toString config.shutdownOrder}"
|
|
] ++ (optional (config.maxStartDelay != null)
|
|
"maxstartdelay = ${toString config.maxStartDelay}")
|
|
);
|
|
|
|
summary =
|
|
concatStringsSep "\n "
|
|
(["[${name}]"] ++ config.directives);
|
|
};
|
|
};
|
|
|
|
in
|
|
|
|
|
|
{
|
|
options = {
|
|
# powerManagement.powerDownCommands
|
|
|
|
power.ups = {
|
|
enable = mkOption {
|
|
default = false;
|
|
type = with types; bool;
|
|
description = ''
|
|
Enables support for Power Devices, such as Uninterruptible Power
|
|
Supplies, Power Distribution Units and Solar Controllers.
|
|
'';
|
|
};
|
|
|
|
# This option is not used yet.
|
|
mode = mkOption {
|
|
default = "standalone";
|
|
type = types.uniq types.string;
|
|
description = ''
|
|
The MODE determines which part of the NUT is to be started, and
|
|
which configuration files must be modified.
|
|
|
|
The values of MODE can be:
|
|
|
|
- none: NUT is not configured, or use the Integrated Power
|
|
Management, or use some external system to startup NUT
|
|
components. So nothing is to be started.
|
|
|
|
- standalone: This mode address a local only configuration, with 1
|
|
UPS protecting the local system. This implies to start the 3 NUT
|
|
layers (driver, upsd and upsmon) and the matching configuration
|
|
files. This mode can also address UPS redundancy.
|
|
|
|
- netserver: same as for the standalone configuration, but also
|
|
need some more ACLs and possibly a specific LISTEN directive in
|
|
upsd.conf. Since this MODE is opened to the network, a special
|
|
care should be applied to security concerns.
|
|
|
|
- netclient: this mode only requires upsmon.
|
|
'';
|
|
};
|
|
|
|
schedulerRules = mkOption {
|
|
example = "/etc/nixos/upssched.conf";
|
|
type = types.uniq types.string;
|
|
description = ''
|
|
File which contains the rules to handle UPS events.
|
|
'';
|
|
};
|
|
|
|
|
|
maxStartDelay = mkOption {
|
|
default = 45;
|
|
type = types.uniq types.int;
|
|
description = ''
|
|
This can be set as a global variable above your first UPS
|
|
definition and it can also be set in a UPS section. This value
|
|
controls how long upsdrvctl will wait for the driver to finish
|
|
starting. This keeps your system from getting stuck due to a
|
|
broken driver or UPS.
|
|
'';
|
|
};
|
|
|
|
ups = mkOption {
|
|
default = {};
|
|
# see nut/etc/ups.conf.sample
|
|
description = ''
|
|
This is where you configure all the UPSes that this system will be
|
|
monitoring directly. These are usually attached to serial ports,
|
|
but USB devices are also supported.
|
|
'';
|
|
type = types.attrsOf types.optionSet;
|
|
options = [ upsOptions ];
|
|
};
|
|
|
|
};
|
|
};
|
|
|
|
config = mkIf cfg.enable {
|
|
|
|
environment.systemPackages = [ pkgs.nut ];
|
|
|
|
jobs.upsmon = {
|
|
description = "Uninterruptible Power Supplies (Monitor)";
|
|
startOn = "ip-up";
|
|
daemonType = "fork";
|
|
exec = ''${pkgs.nut}/sbin/upsmon'';
|
|
environment.NUT_CONFPATH = "/etc/nut/";
|
|
environment.NUT_STATEPATH = "/var/lib/nut/";
|
|
};
|
|
|
|
jobs.upsd = {
|
|
description = "Uninterruptible Power Supplies (Daemon)";
|
|
startOn = "started network-interfaces and upsmon";
|
|
daemonType = "fork";
|
|
# TODO: replace 'root' by another username.
|
|
exec = ''${pkgs.nut}/sbin/upsd -u root'';
|
|
environment.NUT_CONFPATH = "/etc/nut/";
|
|
environment.NUT_STATEPATH = "/var/lib/nut/";
|
|
};
|
|
|
|
jobs.upsdrv = {
|
|
description = "Uninterruptible Power Supplies (Register all UPS)";
|
|
startOn = "started upsd";
|
|
# TODO: replace 'root' by another username.
|
|
exec = ''${pkgs.nut}/bin/upsdrvctl -u root start'';
|
|
task = true;
|
|
environment.NUT_CONFPATH = "/etc/nut/";
|
|
environment.NUT_STATEPATH = "/var/lib/nut/";
|
|
};
|
|
|
|
environment.etc = [
|
|
{ source = pkgs.writeText "nut.conf"
|
|
''
|
|
MODE = ${cfg.mode}
|
|
'';
|
|
target = "nut/nut.conf";
|
|
}
|
|
{ source = pkgs.writeText "ups.conf"
|
|
''
|
|
maxstartdelay = ${toString cfg.maxStartDelay}
|
|
|
|
${flip concatStringsSep (flip map (attrValues cfg.ups) (ups: ups.summary)) "
|
|
|
|
"}
|
|
'';
|
|
target = "nut/ups.conf";
|
|
}
|
|
{ source = cfg.schedulerRules;
|
|
target = "nut/upssched.conf";
|
|
}
|
|
# These file are containing private informations and thus should not
|
|
# be stored inside the Nix store.
|
|
/*
|
|
{ source = ;
|
|
target = "nut/upsd.conf";
|
|
}
|
|
{ source = ;
|
|
target = "nut/upsd.users";
|
|
}
|
|
{ source = ;
|
|
target = "nut/upsmon.conf;
|
|
}
|
|
*/
|
|
];
|
|
|
|
power.ups.schedulerRules = mkDefault "${pkgs.nut}/etc/upssched.conf.sample";
|
|
|
|
system.activationScripts.upsSetup = stringAfter [ "users" "groups" ]
|
|
''
|
|
# Used to store pid files of drivers.
|
|
mkdir -p /var/state/ups
|
|
'';
|
|
|
|
|
|
/*
|
|
users.extraUsers = [
|
|
{ name = "nut";
|
|
uid = 84;
|
|
home = "/var/lib/nut";
|
|
createHome = true;
|
|
group = "nut";
|
|
description = "UPnP A/V Media Server user";
|
|
}
|
|
];
|
|
|
|
users.extraGroups = [
|
|
{ name = "nut";
|
|
gid = 84;
|
|
}
|
|
];
|
|
*/
|
|
|
|
};
|
|
}
|